S chamber dryer up to 200 / 300 °C

When 300 °C is more than enough

The S dryers are designed primarily for drying, vulcanising, preheating, and curing a variety of materials. These dryers’ stainless steel muffles ensure a long service life for these facilities, as they are very chemically and mechanically resistant. Thanks to the horizontal internal atmosphere circulation, S dryers also boast an even temperature distribution.

I’m interested in this furnace

+420 547 230 016 Call us from 8:00 a.m. to 2:00 p.m.
sales@lac.cz We’ll reply within 24 hours.

Furnaces in stock Furnaces and dryers ready for pick-up

Benefits

  • Easy to install, easy to control
  • Custom adjustments
  • Delivery times within 6 weeks
  • 24-month warranty
  • The lowest temperature
  • Even temperature distribution
  • Mechanical durability
  • Chemical durability
  • Easy increasing of heating output
  • Easy maintenance
 
Charge treatment technology
 
(PS = partially suitable)
 
  • Drying
  • Vulcanisation
  • Curing
  • Low-temperature material treatment
  • Incineration, combustion, annealing loss
  • Preheating
  • Heat treatment of metal materials
  • Material testing (PS)
  • Annealing, reducing internal stress
  • Heating
  • Drying moulds and cores
  • Preheating reusable moulds and semi-finished products
  • Preheating castings
  • Preheating moulds
  • Preheating prior to forging
  • Drying
  • Tempering
  • Firinga
S-400_02-chamber-dryer.jpg S 400/02 chamber dryer
S-400_02-chamber-dryer_closed.jpg S 400/02 chamber dryer
S-400_02-chamber-dryer.jpg S 400/02 chamber dryer
S-400_02-chamber-dryer_closed.jpg S 400/02 chamber dryer

Technical parameters

Dryer equipment

Furnace type  Tmax
°C
Recommended operating temperature range in °C Volume in l External dimensions (w × h × d) mm Internal dimensions (w × h × d) mm Shelf pcs Weight in kg Fan pcs Input in kW Protection*  Voltage V Max. load capacity of bottom in kg
S 60/02 200 100 - 200 60 1050×1350×950 450×300×450 1 60 1 2,0 16/1 230 40
S 100/02 200 100 - 200 100 1050×1550×1000 450×500×450 1 180 2 3,0 16/1 230 50
S 250/02 200 100 - 200 240 1400×1550×1200 800×500×600 1 250 1 4,0 16/3 400 70
S 400/02 200 100 - 200 380 1400×1750×1200 800×800×600 1 350 1 4,0 16/3 400 70
S 60/03 300 100 - 300 60 1050×1350×950 450×300×450 1 60 1 3,0 16/1 230 40
S 100/03 300 100 - 300 100 1050×1550×1000 450×500×450 1 180 2 3,0 16/1 230 50
S 250/03 300 100 - 300 240 1400×1550×1200 800×500×600 1 250 1 4,0 16/3 400 70
S 400/03 300 100 - 300 380 1400×1850×1200 800×800×600 1 350 1 6,0 16/3 400 70
*Protection can vary depending on accessories added (at additional cost).
Subject to technical changes.
 

Standard equipment

  • Ht40AL controller (1 programme: 2x run-up, 2x dwell)
  • resistance heating (heating elements)
  • insulation using a mineral-fibre mat
  • thermostat (use as a limit unit)
  • manually controlled ventilation flap for cooling the furnace’s operational space
  • manually controlled suction flap
  • stainless steel muffle
  • stainless steel circulation insert with long service life
  • horizontal internal atmosphere circulation
  • door manually opened towards the side
  • “K” type thermocouple
  • contactless switching relay for noise-free operation
  • door limit switch for safe opening of the furnace
  • stand
  • shelf


Optional accessories available at additional cost

  • Ht205 controller (30 programmes with 15 steps each) / Ht200 controller (30 programmes with 25 steps each, USB interface)
  • graphic temperature recorder
  • automatic ventilation flap for cooling the furnace’s operational space
  • exhaust fan for forced drawing off of flue gases
  • travel wheels
  • transport door opening
  • optimisation of the temperature field for DIN 17052-1 ΔT10 °C in the internal usable space (in an empty furnace at Tmax)
  • measuring loop calibration
  • other shelves
  • EIA-485 or LAN interfaces
  • HtMonit set EV (including software + interface)
  • door opening towards the top (electro-hydraulically)
  • door opening towards the top (pneumatically – pantograph)
  • door opening towards the top (manually – pantograph)
  • relative humidity measurement
  • METREX gas analyser
  • forced cooling
  • door inspection window
  • interior furnace lighting
  • one-handed door closing
Note: When combining accessories (at additional cost), consult with our technical office.


Adaptations for rubber industry

  • exhaust fan in furnace ceiling with automatic flap and insulated fan and suction.
  • the distance between the furnace and the fan must be minimised.
  • air volume extracted based on the furnace volume (e.g. 700 m³/hour drawn off for the SV 3300/250). The furnace must function in underpressure.
  • fan exhaust with tilt away from fan for draining condensate
  • opening at the lowest point in the exhaust for drawing off condensate (to be executed by customer)
  • automatic suction flap on the fan unit
Almost 20.000 furnaces manufactured
Our own team of maintenance technicians
25-member design team
6 custom projects per month
Testing of your specific charges

Furnaces and Dryers>

Refractory Castable Shapes>

https://www.lac.cz/en/furnaces-and-dryers/s-chamber-dryer | https://www.lac.cz/en/furnaces-and-dryers/s-chamber-dryer