K chamber furnace up to 1300 / 1340 / 1400 °C

When you need to fire ceramics in larger amounts

Mainly used in the ceramics sector for firing decorative and industrial ceramics in large amounts. This furnace’s shape and design ensure perfect temperature distribution and the option of quick run-up to the required temperature.

I want this furnace

+420 547 230 016 Call us from 8:00 a.m. to 2:00 p.m.
sales@lac.cz We’ll reply within 24 hours.

Benefits

  • Robust steel structure
  • Ventilation that prevents vapour condensation during firing (reduces corrosion)
  • Heating from five sides, including the bottom
  • Top-quality insulation materials (low electrical energy consumption, option for quick run-up to the required temperature)
  • Solid state relay (smooth and noise-free operation, minimal interference with surrounding equipment)
  • 36-month warranty
K-120_13-chamber-furnace.jpg K 120/13 chamber furnace
K-120_13-chamber-furnace.jpg K 120/13 chamber furnace

Technical parameters

Furnace equipment

Furnace type  Tmax°C Recommended operating temperature range in °C Volume in l External dimensions* (w × h × d) mm Internal dimensions (w × h × d) mm Input in kW Weight in kg Protection**  Voltage V Max. load capacity of bottom in kg
K 50/13 1300 700 - 1250 50 910×1405×1070 350×350×370 5,5 125 16/3 400 50
K 70/13 1300 700 - 1250 80 910×1465×1110 360×450×390 7,5 165 20/3 400 50
K 120/13 1340 700 - 1300 120 1010×1505×1120 450×530×430 10,5 260 20/3 400 80
K 150/13 1340 700 - 1300 150 1010×1600×1140 450×600×450 15 320 25/3 400 80
K 200/13 1340 700 - 1300 200 1060×1825×1185 500×750×460 20 360 40/3 400 120
K 250/13 1340 700 - 1300 230 1095×1775×1230 520×800×510 23 420 40/3 400 120
K 300/13 1340 700 - 1300 310 1105×1820×1345 560×800×710 27 480 50/3 400 200
K 500/13 1340 700 - 1300 490 1460×1825×1460 650×1000×680 40 770 80/3 400 300
K 700/13 1340 700 - 1300 730 1345×1925×1610 750×1100×860 60 990 100/3 400 400
K 1000/13 1340 700 - 1300 1000 1570×2120×1780 800×1220×935 75 2300 125/3 400 500
K 1500/13 1340 700 - 1300 1540 1570×2165×1850 950×1350×1200 110 2950 200/3 400 800
K 2000/13 1340 700 - 1300 2100 2150×2500×2450 1000×1500×1400 130 3300 250/3 400 1000
K 120/14 1400 700 - 1350 120 1010×1535×1140 450×530×500 10,5 230 20/3 400 80
K 150/14 1400 700 - 1350 150 1010×1620×1160 450×600×530 15 280 25/3 400 80
K 200/14 1400 700 - 1350 200 1060×1800×1185 500×750×530 20 310 40/3 400 120
K 250/14 1400 700 - 1350 230 1090×1800×1230 520×800×550 23 360 40/3 400 120
K 300/14 1400 700 - 1350 310 1105×1820×1340 560×800×710 27 420 50/3 400 200
K 500/14 1400 700 - 1350 490 1460×1825×1460 650×1000×750 40 700 80/3 400 300
K 700/14 1400 700 - 1350 730 1550×1925×1610 750×1100×900 60 920 100/3 400 400
K 1000/14 1400 700 - 1350 1000 1570×2120×1775 800×1263×1000 75 1550 125/3 400 500
K 1500/14 1400 700 - 1350 1540 1800×2300×2050 950×1350×1200 110 2600 200/3 400 800
K 2000/14 1400 700 - 1350 2100 2150×2500×2450 1000×1500×1400 130 2900 250/3 400 1000
*For the furnaces’ exterior dimension, the height is given including the stand (K 50 – K 300). The stand’s height is 615 mm. The stated width, meanwhile, includes the controller 160 mm (K 50 – K 300) and the switchboard 250 mm (K 500 – K 2000).
**Protection can vary depending on accessories chosen (at additional cost).
Subject to technical changes.

Standard equipment

  • HtCeramic controller (20 programmes with 15 steps each)
  • SiC plate at bottom of furnace
  • heating spirals made from Kanthal APM (only for furnaces for temperatures of 1400 °C)
  • Alsint ceramic tubes (only for furnaces for temperatures of 1400 °C)
  • stand for K 50 through K 300
  • slide valve for controlling air intake at the bottom of the furnace
  • ventilation bleeder (K 50 – K 300)
  • manually controlled ventilation flap (K 500 – K 2000)
  • power supply cable (K 50/13 – K 300/13 and K 120/14 – K 300/14)
  • door opening towards the left
  • limit switch for safe opening of the furnace

Optional accessories available at additional cost

  • HtIndustry/Ht205 controller (30 programmes with 15 steps each)
  • multi-zone heating system (K 500 – K 2000)
  • heating spirals made from Kanthal APM (for furnaces for temperatures of 1300 °C)
  • Alsint ceramic tubes (for furnaces for temperatures of 1300 °C)
  • manually controlled ventilation flap (K 50 – K 300)
  • automatic ventilation flap
  • graphic temperature recorder (for the K 50 through K 300, the controller and recorder are located in a small switchboard on the side of the furnace)
  • calibration of the controller’s measuring input
  • RS232 or EIA485 calibration (not possible with HtCeramic controller)
  • HtMonit set (software + interface; not possible with HtCeramic controller)
  • overpressure forced cooling
  • custom stand for K 50 through K 300
  • door opening towards the right
 
Note: When combining accessories (at additional cost), consult with our technical office. When combining at least two accessories (automatic ventilation flap, overpressure forced cooling, graphic temperature recorder), an HtIndustry/Ht 205 controller is needed.
Over 13,000 furnaces manufactured
Our own team of maintenance technicians
25-member design team
6 custom projects per month
Testing of your specific charges